Hydrogen retention comparison between LIBS and LIDQMS
- LIBS look into “second order” hydrogen band Littrow
- LIBS shorter delay shots could give number of particle in ground state using calibration free method
- Provide total number of atoms in plasma
- Salvatore evaluate number atoms per laser shot
- LIDQMS plot DT/HDT as an intermediate comparison (Anna) but ultimate aim is quantified data
- LIBS total DT/HDT ratio (Rongxing)
- Further efforts to focus on particular pulses (LIDQMS 855/856)/shots (LIBS 63)
- Jari – send out atomic density data from IBA for HFGC tile
LIBS quantification
- Consider calibration sample for VTT experiment
- There are “IAP samples” available
- Other samples that have IBA?
- Delay times with Littrow and Arielle will be investigated (as per JET experiment and shorter)
- LIBS establish set of lines for analysis (currently not unified)
- Include Avantes line for carbon at “900nm and something”
- Calibration free analysis
- Hydrogen concentration calculation – point 63
- 18 December LIBS meeting online
- Salvatore to show how data was treated
- Profilometery will be needed for ablation rate
LIDQMS quantification
Gennady
- gas puffs for pulse he showed at the meeting
- penning gauge analysis continued….
o H or D calibration for pennings in towers – some ambiguity of hydrogen isotope calibration
- RGA11 vs other RGAs? What pumping fraction is needed for RGA11?
- Other RGAs pumping fraction in 94%
Gas injection comparison of calibration methods
- Gennady and Gabriele to work on alternative calibration method
- 25/9 start with this (others to consider later 4/10 and 28/10 (?)
- Check pulses and data on those data (Anna/Ionut to circulate pulse numbers)
- Need to treat the data in same way as calibration
Comparison with jump method (Laura/Anna)
Conference and publications
- Jari – VTT LIBS experiment – PSI
- Jepu – RE damage on inner limiters – LIBS pulses required – PSI
- Indrek – LIBS IWGL (Poloidal 2X3 and 2X9, 2X17) pulse supporting information on exposure – potentially TDS results – PSI
- Gennady – Calibration procedure for LIBS – PSI
- Anna – comparison of LID-QMS fuel retention with predictions – Hydrogen workshop
- Laura – quantification of LID-QMS using ump method - Include 94%– publication & Hydrogen workshop
- Lidia/Salvatore – depth profiling of HFGC & Tile1using LIBS – PSI
- Pavel – Inner divertor calibration free analysis using LIBS – PSI
- Pavel – Averaging and selection on spectrscopic lines for LIBS analysis (Methodology) – EMSLIBS
- Miro – ex-situ LID-QMS on W-lammellae - PSI
Successes
- Analysis of pumping from Gennady brings LIDQMS closer to a quantified value
- Similar trends in fuel retention across tiles
- Quantification of LIBS using calibration free method
- First absolute HI value in similar order of magnitude to LIDQMS
- Machine learning algorithm progressed for HI
- LIBS depth profiling of each group is converging